Item details
Wilo DL-E 100/145-11/2-S1 Dry-Rotor Twin Pump
Dry-rotor twin pump in inline design for pipe installation or base mounting with integrated frequency converter for electronic control for, among others, constant or variable differential pressure (Δp-c/Δp-v).
Design
Electronically controlled dry-rotor twin pump in inline design with flange connection and automatic power adjustment
Application
Pumping of heating water (according to VDI 2035), cold water and water-glycol mixtures without abrasive substances in heating, cold water and cooling systems.
Equipment/Function
Operating modes
Δp-c for constant differential pressure
Δp-v for variable differential pressure
PID control
Actuator mode (n=constant)
Manual control level
Setting of the differential pressure setpoint
Setting of the speed (manual actuator mode)
Setting of the operating mode
Setting pump ON/OFF
Configuration of all operating parameters
Error acknowledgement
External control functions
Control input "Priority Off"
Control input "External pump changeover" (only effective in twin pump operation)
Analog input 0-10 V, 0–20 mA for actuator mode (DDC) and remote setpoint adjustment
Analog input 2–10 V, 4–20 mA for actuator mode (DDC) and remote setpoint adjustment
Analog input 0–10 V for actual value signal of the pressure sensor
Analog input 2–10 V, 0-20 mA, 4–20 mA for actual value signal of the pressure sensor
Alarm and display functions
Collective fault message SSM
Collective operation message SBM
Data exchange
Infrared interface for wireless data exchange with IR monitor/IR stick
Slot for Wilo IF modules (Modbus, BACnet, CAN, PLR, LON) for connection to building automation
Safety functions
Full motor protection with integrated trip electronics
Access lock
Twin pump management (twin pump or 2 x single pump)
Main/standby operation (automatic fault switchover)
Main/standby operation pump changeover after 24 hours
Addition mode
Addition mode (efficiency-optimised peak load switching on and off)
Your advantages
Energy savings through integrated electronic power adjustment
Easy operation via green button technology and display
Various operating modes: main/standby operation and parallel operation
Configurable fault behaviour tailored to heating and air conditioning applications
Integrated full motor protection (KLF) with trip electronics
Drive
Mains connection
3~380 V, 50/60 Hz
3~400 V, 50/60 Hz
3~440 V, 50/60 Hz
Motor efficiency class: IE4
Power input P1 max: 13000 W
Rated motor power P2: 11 kW
Current (max) Imax: 21 A
Speed max. nmax: 2970 1/min
Emitted interference EN 61800-3
Interference immunity EN 61800-3
Insulation class: F
Motor protection class: IP55
Motor protection: KLF integrated
Installation dimensions
Installation length L0 500 mm
Suction-side pipe connection DNs DN 100
Pressure-side pipe connection DNd DN 100
RRP: 29.006,25 €