Item details
Vötsch VT 7030 S2 Temperature Shock Test Chamber
System for extreme temperature changes
In the context of temperature shock testing, the resistance of components, devices and other products to rapid changes in ambient temperature is tested.
The test specimens are subjected to rapid temperature changes in air with alternating loads of upper and lower temperature.
Based on these cyclic loads and accelerated aging caused by temperature changes, weak points in the test specimen can be made visible.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the transfer basket
All-round grids in the transfer basket secure the test specimens
High air circulation rate, short temperature change times and uniform temperature distribution in the test space
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature cycling unit
Touch panel for convenient editing of simulation programs with graphical display
Minimal energy consumption
No compressed air required
Data for temperature tests in single-chamber operation
Hot chamber:
Temperature shock test chamber 300 l
Temperature range +50 °C to +220 °C
Temporal temperature deviation at center of usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber 300 l
Temperature range -80 °C to +70 °C
Temporal temperature deviation at center of usable space ± 1 K
Spatial temperature deviation 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10%, 50 Hz
Rated power: 30 kW
Rated current: 50 A
Refrigerant: R-404a/R-23
Refrigeration unit: Water-cooled
Weight: approx. 940 kg
Year of manufacture: 1998
Test chamber dimensions: Width 770 mm x Depth 650 mm x Height 610 mm
Housing dimensions: Width 1200 mm x Depth 1800 mm x Height 2050 mm
TS 05
Find more items - new and used - in our shop! International shipping costs on request!
Technical data
Data for temperature tests in single-chamber operation
Hot chamber:
Temperature shock test chamber 300 l
Temperature range +50 °C to +220 °C
Temporal temperature deviation at center of usable space ± 1 K
Spatial temperature deviation ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber 300 l
Temperature range -80 °C to +70 °C
Temporal temperature deviation at center of usable space ± 1 K
Spatial temperature deviation 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Temperature change rate (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10%, 50 Hz
Rated power: 30 kW
Rated current: 50 A
Refrigerant: R-404a/R-23
Refrigeration unit: Air-cooled
Weight: approx. 940 kg
Year of manufacture: 1998
Test chamber dimensions: Width 770 mm x Depth 650 mm x Height 610 mm
Housing dimensions: Width 1200 mm x Depth 1800 mm x Height 2050 mm
Legal information - click for details