Item details
Dosing and storage bunker with frequency control unit
Storage and dosing, especially of sharp-edged, bulky parts,
that are easily caught and difficult to untangle in the sorting pot.
For such parts, a trouble-free sorting process can be ensured by a specific, constant
fill volume in the pot through the bunker.
The bunkers benefit the autonomy of the feed system, as they significantly extend the refill intervals.
Features
– Ensuring a specific, constant fill volume in the sorting pot
– Ensuring a trouble-free sorting process
– low filling height
– Height adjustment if required
Manufacturer: Jürgen Jahn
Model: VBJ 4
Dosing and storage bunker
Volume: 10 liters
Voltage: 230 V
Year of manufacture: 07/2016
Jürgen Jahn Frequency Control Unit:
WaCo B.7/65.1.5 V1
Version with LCD display
one power output, mains voltage compensated for constant output voltage, adjustable 1-230VAC
Sinusoidal output current, max. 6A
Mains frequency independent, adjustable output frequency of 5-200Hz
Automatic detection of mains voltages from 95-253VAC, 50 or 60Hz
Membrane keypad for setting and changing the operating parameters
Separately adjustable limits of the output voltage Umin and Umax
Separately adjustable ramps of the output voltage on and off
Self-protecting through adjustable current monitoring
Backup copy of the operating parameters and factory settings retrievable
Inrush current limitation 4A
Externally controllable via 24VDC
Temperature monitoring of the power output stage
Two-pole main switch
All parameters are displayed in their physical units (V~; A~; °C; Hz; V-; mA-; s)
CE and EMC tested
Operating voltage [VAC] 230 / ±10% (115 / +10%)
Operating frequency [Hz] 50 / 60
Output voltage [VAC] 50 – 250
Output current [A] 0.025 – 5
Degree of protection --- IP54
Find more new and used articles in our shop!
International shipping costs on request!
Technical data
Manufacturer: Jürgen Jahn
Model: VBJ 4
Dosing and storage bunker
Volume: 10 liters
Voltage: 230 V
Year of manufacture: 07/2016
Jürgen Jahn Frequency Control Unit:
WaCo B.7/65.1.5 V1
Version with LCD display
one power output, mains voltage compensated for constant output voltage, adjustable 1-230VAC
Sinusoidal output current, max. 6A
Mains frequency independent, adjustable output frequency of 5-200Hz
Automatic detection of mains voltages from 95-253VAC, 50 or 60Hz
Membrane keypad for setting and changing the operating parameters
Separately adjustable limits of the output voltage Umin and Umax
Separately adjustable ramps of the output voltage on and off
Self-protecting through adjustable current monitoring
Backup copy of the operating parameters and factory settings retrievable
Inrush current limitation 4A
Externally controllable via 24VDC
Temperature monitoring of the power output stage
Two-pole main switch
All parameters are displayed in their physical units (V~; A~; °C; Hz; V-; mA-; s)
CE and EMC tested
Operating voltage [VAC] 230 / ±10% (115 / +10%)
Operating frequency [Hz] 50 / 60
Output voltage [VAC] 50 – 250
Output current [A] 0.025 – 5
Degree of protection --- IP54
Legal information - click for details