Large-scale system for climate testing with S!MCON control
Structure
The system consists of the following main assemblies:
- Walk-in, insulated test chamber
- Air handling room
- Machine unit
- Climate system
- Control cabinet
Test chamber
The fixtures in the test chamber are made of corrosion-resistant material
The test chamber can be illuminated, is walk-in and has a condensate water and cleaning drain.
Air handling room
The air handling room is located behind the air baffle wall in the insulated interior.
It contains the following assemblies necessary for temperature control and is accessible via easily removable panels.
- Test chamber fans
- Heat exchangers
- Electric heaters
- Ventilation and dehumidification unit
- Temperature sensors
In the air handling room, the air is temperature-controlled (cooling/heating), humidified and dehumidified, and circulated by fans.
The air is drawn in from below the ceiling and blown out again at floor level.
Sensors
The temperature and humidity sensors are located behind the air baffle wall in the air handling room.
Machine unit
The machine unit consisting of refrigeration units supplies the air handling room with the required energy.
Climate system
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Temperature range direct: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% r.h.
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5K
Humidity fluctuation: +/- 3 to +/- 5% r.h.
Cooling water data
Connections
Inlet: 2 x R 1 1/2 2"
Return: 2 x R 1 1/2 2"
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10000 N/m²
Rated voltage: 3/N / PE AC 400 V 50 Hz
Rated power: 97 kW
Rated current: 148 A
Refrigerant: R-404A
Dimensions:
Test chamber: Width 3.60 m Height 2.20 m Depth 5 m
Climate chamber divided for transport at a specified point (approx. 2.50 m).
Find more items - new and used - in our shop!
International shipping costs on request!
Technical data
Technical Data
Test chamber volume: approx. 32 m³
Temperature range direct: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1
Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% r.h.
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5K
Humidity fluctuation: +/- 3 to +/- 5% r.h.
Cooling water data
Connections
Inlet: 2 x R 1 1/2 2"
Return: 2 x R 1 1/2 2"
Consumption at full load: max. 16 m³/h
Maximum load on the test chamber floor: 10000 N/m²
Rated voltage: 3/N / PE AC 400 V 50 Hz
Rated power: 97 kW
Rated current: 148 A
Dimensions:
Test chamber: Width 3.60 m Height 2.20 m Depth 5 m
Legal information - click for details