Heraeus Vötsch VCZ 04032 Large-Scale Climate Test Chamber -40 to +100°C with Humidity

US$ 30,361.58*

US$ 25,513.93(Net)

Item number51525
Variation ID54851
ConditionUsed but good
Content1
Manufacturer
Available quantityReady for shipping, delivery in 48h
Stock level1
*Incl. VATexcl. Shipping
Komplett Konzept

Are you from abroad and still want to lease or finance?

Inquire Europe-wide

Item details

Large-scale system for climate testing with S!MCON control

Structure
The system consists of the following main assemblies:
- Walk-in, insulated test chamber
- Air handling room
- Machine unit
- Climate system
- Control cabinet

Test chamber
The fixtures in the test chamber are made of corrosion-resistant material
The test chamber can be illuminated, is walk-in and has a condensate water and cleaning drain.

Air handling room
The air handling room is located behind the air baffle wall in the insulated interior.

It contains the following assemblies necessary for temperature control and is accessible via easily removable panels.
- Test chamber fans
- Heat exchangers
- Electric heaters
- Ventilation and dehumidification unit
- Temperature sensors

In the air handling room, the air is temperature-controlled (cooling/heating), humidified and dehumidified, and circulated by fans.

The air is drawn in from below the ceiling and blown out again at floor level.

Sensors
The temperature and humidity sensors are located behind the air baffle wall in the air handling room.

Machine unit
The machine unit consisting of refrigeration units supplies the air handling room with the required energy.

Climate system
The climate system consists of:
- Steam humidifier
- Dehumidification evaporator


Technical Data

Test chamber volume: approx. 32 m³

Temperature range direct: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1

Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min

Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% r.h.
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5K
Humidity fluctuation: +/- 3 to +/- 5% r.h.

Cooling water data

Connections
Inlet: 2 x R 1 1/2 2"
Return: 2 x R 1 1/2 2"

Consumption at full load: max. 16 m³/h

Maximum load on the test chamber floor: 10000 N/m²

Rated voltage: 3/N / PE AC 400 V 50 Hz
Rated power: 97 kW
Rated current: 148 A

Refrigerant: R-404A


Dimensions:
Test chamber: Width 3.60 m Height 2.20 m Depth 5 m

Climate chamber divided for transport at a specified point (approx. 2.50 m).

Find more items - new and used - in our shop!
International shipping costs on request!


Technical data

Technical Data

Test chamber volume: approx. 32 m³

Temperature range direct: -40 to +100°C
Temperature fluctuation over time in the center of the usable space: +/- 0.5 to +/- 1

Temperature change rate
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min

Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% r.h.
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5K
Humidity fluctuation: +/- 3 to +/- 5% r.h.

Cooling water data

Connections
Inlet: 2 x R 1 1/2 2"
Return: 2 x R 1 1/2 2"

Consumption at full load: max. 16 m³/h

Maximum load on the test chamber floor: 10000 N/m²

Rated voltage: 3/N / PE AC 400 V 50 Hz
Rated power: 97 kW
Rated current: 148 A


Dimensions:
Test chamber: Width 3.60 m Height 2.20 m Depth 5 m

Legal information - click for details

We value your privacy
We use cookies and similar technologies on our website and process personal data of visitors to our website (e.g. IP address), e.g. to personalise content, to integrate media from third-party providers or to analyse access to our website. Data processing only takes place when cookies are set. We share this data with third parties that we name in the settings. Data processing may be carried out with consent or on the basis of a legitimate interest. Consent can be given or refused. There is a right not to consent and to change or withdraw consent at a later date. Please note our Legal disclosure and additional information regarding the use of personal data in our Privacy policy.