TOX CEP 300 Process Monitoring 2-Channel Measuring Systems Measuring System CEP300

US$ 646.33*US$ 8,925.00

US$ 543.13(Net)

Item number10690
Variation ID8453
ConditionUsed but good
Content1
ManufacturerTOX PRESSOTECHNIK
Available quantityReady for shipping, delivery in 48h
Stock level3
*Incl. VATexcl. Shipping
Komplett Konzept

Are you from abroad and still want to lease or finance?

Inquire Europe-wide →

Item details

TOX Process Monitoring CEP 300 2-Channel

The devices of the CEP300 series are measuring systems for process monitoring of the TOX® sheet metal joining process.

In process monitoring, the maximum force during a TOX® joining operation is compared with the setpoints set in the device. A good/bad message is output both on the internal display and via the external interfaces provided for this purpose.

Measuring principle: Force-position monitoring
The force is recorded via a strain gauge force sensor behind the die or punch (monitoring of the peak value).
The position is detected using a precision limit switch +/-0.01mm, from the position measurement the X-dimension can be determined.
For quality inspection, both parameters - force (= peak value of the TOX® joining operation) and X-dimension (residual bottom thickness) - are required.


Technical data

- Desk/wall version
- Housing made of impact-resistant ABS (UL 94HB) RAL 9002
- Large sealable terminal compartment.
- Protection class: IP 54

Electrical data:
- A/D converter: 10 bit = 1024 steps
- Sampling rate: 5 kHz
- Rated load resolution: 840 steps, 1 step (bit) = rated load / 840
- Measurement accuracy: 1%
- Bridge supply: constant current, 17 mA
- Rated load: max. 200 kN
- Program memory: 16 parameter sets
- Measurement data memory: 10 measured values per channel
- Supply voltage: 90 .... 250 V/AC

Power supply
Primary: 90..250 VAC
Secondary: 24V 150mA supply for external sensors,
5V 1A Digital, processor, memory, graphic display
5V/10V Analog: bridge voltage, reference voltage, signal evaluation
Switched-mode power supply: Type 10 W max. 20 W

Sensors Channel 1 and Channel 2
The force measurement of Channel 1 and Channel 2 is optionally via a
strain gauge force sensor or a sensor with standardized process signal. The
input is selected in the "Configuration" menu.
Rated load: Adjustable via menu
Sampling rate: 5 kHz

DMS I (TOX® standard sensor)
The DMS is supplied via a constant current source:
IDMS: 17mA
UDMS: 5V/10V(adjustable)
Standardization: 8.40

Display
Alphanumeric LC display with backlight
Resolution: 4 lines, 20 characters each
Color: green-yellow
Contrast adjustable via potentiometer
Keyboard
Cursor / function keys 4
ENTER 1
ESC 1

The keyboard is housed on a separate key board board and connected to the
main board via ribbon cable.

Item condition: used

Original price 8925,- €


Legal information - click for details

We value your privacy
We use cookies and similar technologies on our website and process personal data of visitors to our website (e.g. IP address), e.g. to personalise content, to integrate media from third-party providers or to analyse access to our website. Data processing only takes place when cookies are set. We share this data with third parties that we name in the settings. Data processing may be carried out with consent or on the basis of a legitimate interest. Consent can be given or refused. There is a right not to consent and to change or withdraw consent at a later date. Please note our Legal disclosure and additional information regarding the use of personal data in our Privacy policy.