Chilworth JCI 164 High Voltage Adapter Voltmeter Adapter Component

US$ 2,016.52*

US$ 1,694.55(Net)

Item number62128
Variation ID65492
ConditionUsed but very good
Content1
ManufacturerMusterfirma
Available quantityReady for shipping, delivery in 48h
Stock level1
*Incl. VATexcl. Shipping
Komplett Konzept

Are you from abroad and still want to lease or finance?

Inquire Europe-wide →

Item details

Chilworth JCI 164 High Voltage Adapter

General Description
The JCI 146 is a voltmeter adapter component designed for integration into broader experimental systems.
In combination with our JCI 140, the system enables the measurement of current-carrying conductors with voltages up to ± 60 kV DC with an accuracy of ± 2% (nominal) and minimal loading effects on the device under test.

The high input impedance and low capacitance of the JCI 146 are suitable for more accurate DC voltage measurements.
Other conventional techniques for direct measurement of high voltages (e.g. high voltage meters, capacitive and resistive divider networks, etc.) often provide inaccurate results due to loading effects caused by the measurement setup.

This device can be used for cross-checking the calibration and accuracy of high voltage sources by power utilities, calibration test houses, and cable manufacturers, to name a few application areas.

Features
Direct measurement of current-carrying conductors up to ± 60 kV DC
Highly accurate measurement with minimal loading effects
Low input capacitance
Very high input impedance, typically 10 13 Ohm
Can be used in a wider range of test, measurement, and research systems
Optional battery-powered and optically isolated data acquisition module available for remote monitoring of high voltage.

Specification
Measurement:
Maximum Measurement Voltage ± 60 kV DC
Input Impedance:
Not less than 4.7x10 13 Ohm at ± 50 kV
Input Capacitance:
32 pF (± 20%) (JCI 146 chamber only)
Installation:
Fixed installation (permanent earth connection required)
Usage:
Used in Faraday cage environments (not included as standard)
Accuracy:
Nominal ± 2%
Attenuation: 1/10
of the reading displayed on JCI 140

For use with the JCI 140 static monitor and JCI 165 data acquisition module

Find more items - new and used - in our shop!
International shipping costs on request!


Legal information - click for details

We value your privacy
We use cookies and similar technologies on our website and process personal data of visitors to our website (e.g. IP address), e.g. to personalise content, to integrate media from third-party providers or to analyse access to our website. Data processing only takes place when cookies are set. We share this data with third parties that we name in the settings. Data processing may be carried out with consent or on the basis of a legitimate interest. Consent can be given or refused. There is a right not to consent and to change or withdraw consent at a later date. Please note our Legal disclosure and additional information regarding the use of personal data in our Privacy policy.