Andreas Schmid KK 5.500/-40/+130 climate chamber climate cabinet -40 °C to +130 °C

US$ 15,692.50*

US$ 13,186.98(Net)

Item number52517
Variation ID55843
ConditionUsed but good
Content1
Manufacturer
Available quantityReady for shipping, delivery in 48h
Stock level1
*Incl. VATexcl. Shipping
Komplett Konzept

Are you from abroad and still want to lease or finance?

Inquire Europe-wide

Item details

Andreas Schmid Climate Chamber -40 °C to +130 °C

The test chamber is a monoblock construction.
It consists of the actual test space with the recirculating air mixing chamber and the necessary heat exchanger, as well as the unit frame, which is arranged behind the test space and is a fixed component of the system.
Control and regulation are located on the front side of the unit frame.

Chamber design: Monoblock, welded

Dimensions

  • Test space: (W x D x H) 3000 x 1150 x 1600 mm
  • External dimensions: (W x D x H) 3740 x 1390 x 1880 mm
  • Unit frame: (W x D x H) 1500 x 1000 x 1000 mm
  • Door double leaf: (W x H) 3000 x 1600 mm
  • Test space window, heated: (W x H) 300 x 500 mm

Interior lining

  • Walls and ceiling: V2A sheet metal, 1 mm smooth
  • Floor: V2A sheet metal, 2 mm embossed
  • Floor load: 20000 N/m²
  • Wheel load: 3000 N/4cm², 200 mm rubber wheel
  • Insulation: 120 mm PUR, CFC-free B1 according to DIN 4102
  • Exterior cladding: steel sheet 0.6 mm, painted and to RAL 9002
  • Temperature range: -40 °C to +130 °C
  • Temperature constancy +- 1.0 K - temporal
  • Climate range: +10 °C to +90 °C
  • Humidity constancy: +-3% r.h.

Average rate of temperature change: 3K/min on average
from: -40 °C to +130 °C and vice versa

Humidifier: Steam humidifier for operation with fully demineralized water supplied on-site

Refrigeration supply: refrigeration compressor, water-cooled
Refrigerant: R 404 A
Cooling water inlet temperature: 15 °C
Ambient temperature: 35 °C
Heat supply: electric resistance heating

Electrical data
Voltage: 400 V / 3 Ph / N + Pe / 50 Hz

The current consumption depends on the operating conditions for the:

Cooling operation: 31 A
Heating operation: 26 A
Climate operation: 50 A


Further items - new and used - can be found in our shop! International shipping costs on request!


Technical data

Chamber design: Monoblock, welded

Dimensions
Test space: (W x D x H) 3000 x 1150 x 1600 mm
External dimensions: (W x D x H) 3740 x 1390 x 1880 mm
Unit frame: (W x D x H) 1500 x 1000 x 1000 mm
Door double leaf: (W x H) 3000 x 1600 mm
Test space window, heated: (W x H) 300 x 500 mm

Interior lining
Walls and ceiling: V2A sheet metal, 1 mm smooth
Floor: V2A sheet metal, 2 mm embossed
Floor load: 20000 N/m²
Wheel load: 3000 N/4cm², 200 mm rubber wheel
Insulation: 120 mm PUR, CFC-free B1 according to DIN 4102
Exterior cladding: steel sheet 0.6 mm, painted and to RAL 9002

Temperature range: -40 °C to +130 °C
Temperature constancy +- 1.0 K - temporal
Climate range: +10 °C to +90 °C
Humidity constancy: +-3% r.h.

Average rate of temperature change: 3K/min on average
from: -40 °C to +130 °C and vice versa

Humidifier: Steam humidifier for operation with fully demineralized water supplied on-site

Refrigeration supply: refrigeration compressor, water-cooled
Refrigerant: R 404 A
Cooling water inlet temperature: 15 °C
Ambient temperature: 35 °C
Heat supply: electric resistance heating

Electrical data
Voltage: 400 V / 3 Ph / N + Pe / 50 Hz

The current consumption depends on the operating conditions for the:

Cooling operation: 31 A
Heating operation: 26 A
Climate operation: 50 A

Legal information - click for details

We value your privacy
We use cookies and similar technologies on our website and process personal data of visitors to our website (e.g. IP address), e.g. to personalise content, to integrate media from third-party providers or to analyse access to our website. Data processing only takes place when cookies are set. We share this data with third parties that we name in the settings. Data processing may be carried out with consent or on the basis of a legitimate interest. Consent can be given or refused. There is a right not to consent and to change or withdraw consent at a later date. Please note our Legal disclosure and additional information regarding the use of personal data in our Privacy policy.